Final Year Project Based On "Automatic Smoke Detector Alarm" | How To Make "Smoke Detector Alarm Circuit"
A Quick Overview Of Smoke Sensors:
- Smoke Detectors Come In Two Different Varieties. Ionization Smoke Detectors And Optical Or Photoelectric Smoke Detectors.
- A Light Source, Such As An Led, And A Light Detector, Such As A Photocell, Make Up Optical Smoke Detectors.
- As Long As Light Shines On The Photocell, It Will Conduct. The Photocell Doesn't Conduct When There Is Smoke Because The Source's Light Is Obscured.
- Two Electrodes And An Ionization Chamber With Ions Are The Components Of Ionization Smoke Detectors. The Ions Travel Freely And The Electrodes Conduct Normally When There Is No Smoke.
- Smoke Causes The Chamber To Fill With Smoke, Which Stops The Ions From Moving. The Electrodes Are No Longer Conducting.
- The Conductivity Conditions May Vary Depending On The Sensor Type And Manufacturer, But The Concept Is The Same.
- A Smoke Detector's Output Can Be Used To Set Up An Alarm System.
- The Mq-2 Gas/smoke Sensor Is The Sensor Utilised In This Research. It Is Sensitive To Flammable Gases Used In Industry, Including Butane, Alcohol, Hydrogen, Smoke, Methane, And Hydrogen.
- Aluminum Oxide (Al2o3) Is Used For Both Of Its Electrodes, While Tin Dioxide (Sno2) Is Used For The Heating Element, Which Also Serves As The Primary Sensing Layer.
- Cables and Connectors
- Diodes
- PCB and Breadboards
- LED
- Push Buttons
- Switch
- IC
- IC Sockets
- Battery
- I R Transmitter Receiver
- 555 Timer IC
- Buzzer
- Resistors
- Capacitors
- Transistors
- In The Event Of A Fire, The Interior Spaces Of The Building Are Filled With Smoke. This Smoke Cloud Gradually Gets So Thick That It Significantly Reduces Visibility. This Information Can Be Used To Build A Straightforward Smoke Detector Alarm That Can Warn Nearby Households Of A Fire Outbreak.
- Because It Doesn't Use Expensive Smoke Detecting Sensors, The Automatic Smoke Detector Alarm Is Quite Small.
- It Contains Two Infrared Sensors That Continuously Check The Lighting Conditions In The Area Where They Are Mounted.
- If A Fire Starts, Smoke Is Produced And Travels Throughout The Building. The Infrared Sensors' Ability To Detect Smoke Get Obscured After It Enters The Smoke Detector Module.
- The Detector Module Activates A Fire Alarm As A Result. Residents Nearby Can Become Aware Of The Fire And Leave The Area After Hearing This Alarm.
- The Alarm Continues To Ring While There Is Smoke Present And Turns Off Once The Smoke Has Cleared.
- The Opaqueness Attribute Of Smoke Serves As The Organizing Basis For This Endeavour. The Infrared Sensors Are Constantly Visible To One Another In The Absence Of Smoke.
- The Sensor Output Changes As Soon As Smoke Enters The Field Of View And Blocks The Sensor Signal.
- The System Detects This Alteration And Sounds An Alarm To Warn The Nearby Residents Of The Fire Outbreak.
Block Diagram:
Important Notes:-
Trending Posts This Month:-
Solved Examples Problems On Star-Delta Transformation Or Conversion
Solved problem based on Norton’s Theorem
Solved Problem Based On Superposition Theorem
Example Solved Problems Based On Thevenin Theorem Circuit
Tricky Solutions For Equivalent Series-parallel Resistance Problems With
Examples
Solved Problem Based On Maximum Power Transfer Theorem
Mesh-analysis - Loop-analysis -Maxwell's Current Analysis | Electrical
Delta To Star Transformation Or Delta To Star Conversion and Its Formulas
Superposition Theorem And Method Of Solving Superposition Theorem
Reading Problems Based On Superposition Theorem Example & Solved
Formula's